-40%

Refrigerant Halogen Leak Detector HVAC R134a R410a R22a Air Conditioner Checker

$ 13.19

Availability: 100 in stock

Description

Refrigerant Halogen Leak Detector HVAC R134a R410a R22a Air Conditioner Checker
Product Overview:
For all halogen leak detectors in our shop, model wjl600, cld100, hld100+, hld200+ are corona types;
Elitech WJL6000 R134a R410a R22a Refrigerant Halogen Leak Detector Air HVAC Checker
Elitech WJL-6000 Halogen Leak Detector 100% Elitech new Halogen Gas HFC CFC Refrigerant Leak Detector Checker.
Its advanced detection technology enables it to recognize all HFC (134a) CFC refrigerants. Audio and visual alerts warn of any leakages, no matter how small.
Main features:
Detect all kinds of halogen refrigerant gases;
Sensitivity adjusted at any time and it can be adjusted automatically to the best state of detecting;
Inner precise IC with ultra-low power consumption circuit design, more stable, longer battery life;
Dual-color visual display of battery voltage;
Excellent sensor,high sensitivity,long lifetime.
Applications:
The Elitech WJL-6000 Halogen Leak Detector  may also be used to:
It will respond to all halogenated (contains Chlorine of Fluorine) refrigerants. This includes, but is not limited to:
CFCs e.g.R12, R11,R500,R503 etc. HCFCs e.g. R22,R123, R124,R502 etc. HFCs e.g. R134a, R404s, R125 etc.
Blends such asAZ-50. HP62. MP39 etc.
Detect Ethylene Oxide gas leaks in hospital sterilizing equipment (it will detect the halogenated carrier gas).
Detect SF-6 in high voltage circuit breakers.
Detect most gases that contain chlorine, fluorine and bromine (halogen gases). Detect cleaning agents used in dry cleaning
applications such as per chloroethylene. Detect halogen gases in fire-extinguishing system.
Technical parameters:
Operating temperature: 0°C-52 °C (30°F to 125°F);
Maximum sensitivity: 6 g/yr,for all halogenated refrigerants;
Battery life: approximately 50 hours normal use;
Response time: Instantaneous ;
Operating mode: continuous,no limitation;
Fixed probe length: 20cm;
Dimensions: 22.9*6.5*6.5 (cm);
Warm-up time: approximately 6 seconds;
Reset time: two to ten seconds;
Power supply  6V DC, four AAA alkaline batteries.
The battery voltage indicator:
The light on the front panel is used for leakage warning instructions and battery voltage.
Green - the battery voltage is normal, suitable for the job
Orange - the battery voltage is close to the limit work, need to be replaced as soon as possible
Boot automatically reset/follow the circuit:
WJL - 6000 is a boot) and automatic reset function, halogen gas levels can ignore the environment.
Boot reset: the instrument after startup, can automatically adjust circuit within 6 s to ignore probe existing
Refrigerant concentration level, the state of detection, users such as beside the leakage source boot, party
Seeking higher concentration of leakage source. Instrument can also be moved to clean up in the air, with adjustable
Whole to maximum sensitivity, the above zero concentration level of leakage can be detected.
Automatic follow circuit: when the instrument is in a state detection, automatic circuit will follow halide in the environment
The change of gas concentration, to prevent false alarm.
What's included:
1 x Detector
1 x Carry/storage case
1 x Instructions
If there is any questions, just contact us, we will alway be here for you.