-40%
NEW BACHARACH INFORMANT 2 REFRIGERANT FREON COMBUSTIBLE GAS LEAK DETECTOR
$ 237.59
- Description
- Size Guide
Description
Bacharach Informant 2 - Combustible and Refrigerant Leak DetectorThe Informant® 2 leak detector allows pinpoint detection of both refrigerant and combustible gas leaks with the same instrument.
Its unique combination of state-of-the-art patented sensor technology, advanced software design, and microprocessor controlled circuitry offers you unmatched precision coupled with tremendous speed. It is unquestionably the most sensitive, most reliable, most accurate leak detector on the market today. And the fastest.
Swap sensor tips within seconds and never worry about adjusting sensitivity levelsit's taken care of automaticallyeven where high levels of background vapors or refrigerants are present. The refrigerant sensor tip is finely tapered to 0.2 inch diameter, so you can get in between coils and fittings, gaining access to hard to reach areas.
The Informant® 2 leak detector features an audible indicator with a mute option coupled with sequential LEDs to monitor increasing concentrations of refrigerant or combustible gases. Dual bar graph displays offer visual confirmation no matter what position the instrument is in. A flashing light at the tip of the probe helps to visually define your sampling location.
Features & Benefits
One instrument two functions
Lightweight and ergonomically designed
Swap sensor tips in seconds
Microprocessor controlled for accuracy and reliability
Sensitivity is automatically adjusted
Sensors are the industry's most responsive
Hydrophobic filter prevents moisture contamination
Optional rubber boot holds MagLite® flashlight
Sequential flashing probe tip, dual LED displays and loud tick rate indicates relative concentration levels
Detects all halogens and combustibles
Response time is two-tenths of one second
Probe length adjustable from 3" to 20
Specifications
Sensing Elements
Refrigerant - Heated Diode, U.S. Patent No. 5,932,176
Combustible - Patented semiconductor type, 5 year typical life, plug-in replacement
Refrigerants Detected
All CFC, HCFC and HFC refrigerants including: R-12, R-22, R-123, R-134a and blends R-404A, R-408A, R-409A and R-410A (i.e., any refrigerant containing Chlorine, Fluorine or Bromine gas)
Combustible Gases Detected
All combustible gases and vapors
Alarm Sensitivity
Refrigerant 0.25 oz/year of R134a (hardest to detect refrigerant)
Combustibles Minimum 50 PPM (Methane)
Alarm Types
: Audible and dual visual LEDs
Power Source
: Four (4) AA disposable alkaline batteries included
Warm-up Time
: 10 seconds
Response Time:
Instantaneous
Battery Life
:
4 to 5 hours, under typical intermittent operation.
Probe
:
20" (50.8 cm) maximum length, fully extended; 3" (7.62 cm) if wrapped around instrument. Includes LED indicator
Size:
1.75"W (4.44cm) x 9.62"L (24.43cm) x 2.25"H (5.72 cm)
Weight
: 0.86 lbs. (0.39 kg) with batteries
Agency Approvals
Refrigerant UL listed in accordance with SAE J1627
Combustible MET Lab certified to UL 913, intrinsically safe for use in Class I, Division 1, Group D hazardous areas.
CE-Mark
: Independently tested